HJ Bar
Hybrid Aluminum/Stainless Steel Conductor System
HJ-Bar combines the high conductivity of aluminum with the corrosion resistance and durability of a stainless steel cap into a single conductor bar. Unlike other aluminum/steel designs that use aluminum conductors bolted to standard steel rail to improve electrical performance, HJ-Bar optimizes the aluminum/steel electrical interface through a proprietary manufacturing process that provides continuous contact pressure along the entire length of the rail. This design results in a lightweight, durable and low-maintenance conductor rail.
Features
- Patented manufacturing process ensures low electrical resistance between aluminum and stainless steel components through continuous contact pressure
- Full range of standard components including hangers, anchors, feeders, splice joints, expansion joints, isolation joints and collector assemblies
- Service-proven stainless steel cap design yields high strength without shifting or peeling from the aluminum bar, even under extreme loads
- Hard 3/16” thick stainless steel running surface for extended life under continuous use
- Systems are engineered to customer specifications, including system layout and installation support
- No cleaning or conditioning of the conductor surface required for infrequent use situations
Project Engineering and On-Site Installation Support
TransTech’s engineers custom-configure our products and systems to meet each customer’s unique application requirements. We provide on-site technical installation support and layout drawings to our customers and their installation teams.

| Series | A | B | Wt/Ft |
| 1750 |
2.5” |
2.25” |
7.3 lbs |
| 4000 |
4.0” |
4.5” |
12.2 lbs |
| 6000 |
5.0” |
5.5” |
16.1 lbs |
Specifications
- 1750, 4000 and 6000 amp capacities available
- AC or DC voltages up to 4160V based on insulator selection
- 30 foot standard rail lengths, custom lengths available
- Compatible with the corresponding ‘H’ and ‘HC’ conductor bar system components
- Suitable for top-running, under-running and side-running installations, with both tracking and non-tracking collectors
|
|
 |
|

|